Featured Products

Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.

Welcome to FLOWTECH MEASURING INSTRUMENTS P LTD.

Effluent Water Digital Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Model EMFM-01
Display Digital

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type

Digital Water Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMF-01
Display Digital

FLOWTECH Make Digital Water Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Electromagnetic Water Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0552

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Magnetic Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-02

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail :

Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type

Electromagnetic Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0608

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Sanitary Electromagnetic Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH

Our company is a renowned name in the area of Sanitary Electromagnetic Flow Meter. A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. The physical principle at work is electromagnetic induction. This one from our side requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube.

Features:

Accurate electromagnetic induction
Perfect magnetic field is applied
Correct measurement

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Meter Size : 1” to 4”
Pressure : 40 Bar max
Media Temperature : 150C max
Ambient Temperature: 4 to 50C
Material : Pipe : SS304
Liner: PTFE Food Grade
Electrodes :SS316L
Coil Housing : SS304/SS316
End Connections: SS304/SS316
Min.Media conductivity: 5 micro-siemens per cm
Output : 1) 4 to 20 mA proportional to flow Rate, isolated from input,body and power supply (Standard). 2) Pulse Output, open collector type, proportional to totalizing rate (Optional)
Local Display (Optional) : a) Flow Rate, 3½ digit LCD/LED. b) Total Quantity, 8 Digit LCD/LED
Accuracy : 0.5% of reading from 100% to 10% flow rate
Flow Velocity Range : 0.5 m/s to 5 m/s. (Higher velocities can be catered on request)
Power Supply : 1) 110 Vac/230 Vac,50/60 Hz.(Standard) 2) 24 Vdc/12 Vdc. (Optional)
Power Rating : 10VA Max
Ingress Protection: IP68 for Primary Flow Sensor,IP65 for flow Transmitter

Water Flow Rate Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-324

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Magnetic Water Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Flow range 3 to 1271 m3/hr

DESCRIPTION

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

WORKING PRINCIPLE

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

TECHNICAL DETAIL

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Digital Flow Meters Water

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMFM-0944
Display Digital

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Digital Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand Flowtech
Flow range(Min-Max) 3 - 1271 m3/hr
Display Local, Remote
Application Media Water
Operating Temperature (Celsius) 120 Deg C
Operating Pressure 25 Kg/cm2
Line Size 15 NB to 300 NB

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Magnetic Flows Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-121
Flow range 1m3/hr to 1500m3/hr

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Water Pipe Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Display Local, Remote
Flow range(Max-Min) 3 to 1271 m3/hr
Application Media Water

DESCRIPTION

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

WORKING PRINCIPLE

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

TECHNICAL DETAIL

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Hot Water Flow Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMFM-054
Application Industrial

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Hot Water Flows Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand Flowtech
Display Local, Remote
Flow range(Max-Min) 3 to 1271 m3/hr
Operating Temperature (Celsius) 120 Deg C
Application Media Water
Line Size 15 NB to 300 NB
Operating Pressure 25 kg/cm2

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Water Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0634

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Flow range 3 - 1271 m3/hr

DESCRIPTION

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

WORKING PRINCIPLE

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

TECHNICAL DETAIL

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Water Flow Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand Flowtech
Display Local, Remote
Flow range(Max-Min) 3 to 1271 m3/hr
Operating Temperature (Celsius) 120 Deg C
Application Media Water
Line Size 15 NB to 300 NB
Operating Pressure 25 Kg/cm2

ADDMAS full bore meter is a cost effective flow meter for conductive liquids such as Raw Water, effluents, Potable water and industrial chemical. Using time proven electromagnetic flow metering principle, ADDMAS flow meters are available for pipes from ½” NB to 6” NB. Since there are no moving parts, the flow meter gives years of maintenance free service. Its performance is independence of temperature, pressure, density and viscosity of medium. The Water Flow Meter is obstruction less and hence the pressure drop is almost negligible. ADDMAS has all the features required in field mountable metering equipment. These include-weather proof / flame proof enclosure, RS485 communication option , with 4 to 20 mA isolated Current output for Flow signal transmission option for process control. The converter is available as field mounted – IP65 protection category. An optional batching controller also available on request.It works on Faraday’s Law of Electromagnetic induction. A magnetic field is generated by magnetic coil. The fluid flowing through this magnetic field generates EMF (Voltage) which is proportional to the flow velocity. This EMF is measured by the Electrodes giving corresponding output. Used for precision measurement of any conducting liquid or slurry that is flowing in closed pipes. 

High Accuracy flow metering
Optional Digital Transmission
2 Line Alpha numeric back lit display
No pressure drops in process.
Line size 15 NB to 300 NB
Accuracy = 1% of reading
Flow range 0.5 to 10 m/s
Easy maintenance as no moving parts
Min.conductivity : 5 us/cm
Output :4-20 ma,Relay and RS485
Protection : Cast Aluminum lP65 field / wall mounted
Process Temp: + 150 degree max.
Lining : PTFE / Rubber / PP

Data Acquisition Software Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Set
Flow range 3 to 1271 m3/hr
Brand FLOWTECH
Display Local

Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:
 

Scientific laboratory
Research centres
Chemical industries

Specifications:
Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Online Effluent Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-108

Description

Flowtech Make Electromagnetic Flow Meter Are Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.

Working Principle

This Is Working On The Principal Of Faraday`s Law Which States That When A Conductor Moves Through A Magnetic Field Of A Given Strength A Voltage Is Produced In The Conductor And Proportion To The Relative Velocity Between The Conductor And The Magnetic Field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Water Digital Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMFM-03
Application Industrial

Description

Flowtech Make Electromagnetic Flow Meter Are Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.

Working Principle

This Is Working On The Principal Of Faraday`s Law Which States That When A Conductor Moves Through A Magnetic Field Of A Given Strength A Voltage Is Produced In The Conductor And Proportion To The Relative Velocity Between The Conductor And The Magnetic Field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Effluent Water Flow Meter

  /> </div>
<div class=


Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0712

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:
Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Milk Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Design Type Standard

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Water Flows Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0203

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Electromagnetic Flowmeter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-063

DESCRIPTION

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

WORKING PRINCIPLE

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

TECHNICAL DETAIL

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Flow Meter With Data Acquisition Software

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Line Size 25 NB TO 300 NB

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Sanitary Liquid Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Unit
Brand FLOWTECH
Model SEMFM-0250

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Sanitary Magnetic Flow Meter

  /> </div>
<div class=


Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH

FLOWTECH Make Sanitary Magnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Electro Magnetic Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-99

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:

Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Flow Meter With Data Acquisition Softwares

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand Flowtech
Display Local
Flow range(Min-Max) 3 to 1271 m3/hr
Application Media Water
Operating Temperature (Celsius) 120 Deg C
Line Size 15 NB to 300 NB
Operating Pressure 25 kg/cm2

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

Scientific laboratory
Research centres
Chemical industries

Specifications:


Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Electromagnetic Flows Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-024

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Sanitary Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-108

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Electromagnetic Digital Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

WORKING PRINCIPLE

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

TECHNICAL DETAIL

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Magnetics Flows Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0042

Description

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail

Nominal Dia (mm) : 15 to 400

Material of Construction : MS, SS 304, SS 316 & SS 316L

Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum

Process Pressure : Max. 25 kg/cm2

Process Temperature : Max. 150C

Flow Tube Material : SS 316

End Connection : Flange/Wafer

Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF

Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum

Accuracy : ± 1% FSD Optional: ±0.5% FSD.

Repeatability : 0.3%

Display : 2 Line Alfa Numeric LCD

Display Version : Integral /Remote

Display Unit : Standard Unit in M3, Litre

Power Supply : 230 VAC, 110 VAC & 24 VDC

Output : Std. 4 – 20 mA

Protection Class for Sensor : IP 65

Protection Class for Transmitter : IP 65

Cable Length for Remote : 10 meters.

Installation : Inline Flange Type

Data Acquisition Software Electromagnetic Flow Meter

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0981

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:
 

Scientific laboratory
Research centres
Chemical industries

Specifications:


Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Industrial Flow Meters

  /> </div>
<div class=

Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Line Size 15 NB TO 300 NB
Application Media Water

Description:

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:

Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC 24 VDC
Output : Std. 4 – 20 mA / RS 485
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type

Digital Electromagnetic Flow Meter

  /> </div>
<div class=


Product Details:

Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMFM-99
Application Media Water

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
Scientific laboratory
Research centres
Chemical industries

Specifications:


Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
Acrylic And Glass Tube Manometer, Acrylic Body Inclined Tube Manometer, Acrylic Body Manometers, Acrylic Body Rotameter For Liquid And Gases, Acrylic Body Rotameter With Valve, Acrylic Body Single Limb Manometer, Acrylic Body U Tube Manometer, Acrylic Bodys Rotameters, Acrylic Flanged Rotameters, Acrylic Flow Meter Rotameters, Acrylic Flow Rota Meter, Acrylic Manometer, Acrylic Plastic Body Rotameters, Acrylic Rotameter, Acrylic Rotameters, Acrylics Body Rotameter, Acrylics Body Rotameters, Acrylics Bodys Rotameters, Air Flow Rotameter, Air Flow Rotameters, Air Flows Rotameter, Air Moisture Separator, Air Moisture Separators, Air Rotameter, Air Velocity Measuring Kit, Analog Fuel Flow Meter, Board Level Indicator, Board Type Level Indicator, Boat Fuel Flow Meter, By Pass Glass Tube Rotameter, By Pass Glass Tube Rotameters, By Pass Rota Meters, By Pass Rotameter For Chemical Process Industries, By Pass Type Rotameter, Bypass Rotameter, Capsule Type Level Indicator, Cell Cast Acrylic Rotameters, Chemical Industries Reflex Transparent Level Gauge, Chemical Rotameters, Conductivity Float Type Level Switches, Conductivity Level Switch, Conductivity Level Switches, Conductivity Points Level Switches, Conductivity Type Level Switch, Conductivity Type Levels Switches, Conductivity Type Liquid Level Switch, Data Acquisition Software Electromagnetic Flow Meter, Data Acquisition Software Flow Meter, Data Logger Flow Meter, Data Logger With Flow Meter, Data Logger With Water Flow Meter, Diesel Flow Meter, Diesel Fuel Flow Measurement, Diesel Fuel Flow Meters, Diesel Fuel Flows Meter, Diesel Fuel Meter, Digital Data Logger Flow Meter, Digital Electromagnetic Flow Meter, Digital Flow Meter, Digital Flow Meters Water, Digital Water Flow Meter, Displacer Type Level Switches, Displacer Type Levels Switch, Displacer Type Levels Switches, Double Window Flow Indicators, Double Window Sight Glass, Double Window Sight Glass Indicator, Double Window Sight Glass Indicators, Double Window Sight Glasses, Effluent Water Digital Flow Meter, Effluent Water Flow Meter, Electro Magnetic Flow Meter, Electromagnetic Digital Flow Meter, Electromagnetic Flow Meter (Magflow Meter), Electromagnetic Flow Meter With Data Logger, Electromagnetic Flowmeter Magnetic Flow Convertor, Electromagnetic Flows Meter, Electromagnetic Flows Meters, Electromagnetic Water Flow Meter, Filters Flowtech Make Sight Flow Indicator, Flange Assemblies, Flange Tape Type Rota Meters, Flanged Connections Rotameter, Float And Board Level Indicator, Float And Board Liquid Level Indicator, Float Board Level Indicator, Float Level Indicators, Float Level Switch, Float Levels Switch, Float Operated Level Switches, Float Switches, Float Type Level Switch, Float Type Tank Level Indicator, Floats Levels Switch, Flow Measurement Orifice Plate, Flow Measuring Instrument, Flow Measuring Instruments, Flow Meter, Flow Meter Orifice Plate, Flow Meter Rotameters, Flow Meter With Data Acquisition Software, Flow Meter With Data Acquisition Softwares, Flow Meters, Flow Rotameter, Flow Rotameters, Flows Measuring Instrument, Flows Measuring Instruments, Flows Measurings Instrument, Flows Measurings Instruments, Flowtech Acrylic Body Rotameters, Flowtech Glass Tube Rotameters, Flowtech Metal Tube Rotameter, Flowtech Type Level Transmitter, Fluid Level Gauge, Fluid Level Indicator, Fluid Level Indicators, Fluid Level Indicatorss, Fluid Level Indicatorsss, Fluid Level Switch, Fuel Flow Meter Aviation, Fuel Flow Meter Marine, Fuel Flow Meters, Fuel Flow Meters For Boats, Fuel Flows Meter, Fuel Flows Meters, Fuel Meter, Fuel Oil Tank Level Indicator, Fuel Tank Level Indicator, Fuel Tank Level Indicators, Fuel Tank Level Indicatorss, Fuel Tank Levels Indicators, Fuels Flow Meter, Fuels Flows Meters, Full Bore Type Electromagnetic Flow Meter, Gas Flow Meter, Gas Flow Rotameter, Gas Flow Rotameters, Gas Flows Rotameter, Gas Flows Rotameters, Gas Rotameter, Gas Rotameters, Glass Level Indicator, Glass Rotameter, Glass Tube Rota Meters, Glass Tube Rotameter, Glass Tube Type Purge Rotameter, Glass Tube Type Rotameter, Glass Tube Types Rotameter, Glass Tubes Rotameter, Glass Tubes Rotameters, High Temperature Reflex Transparent Level Gauge, Hot Water Flow Meter, Hot Water Flow Meters, Hot Water Flows Meter, Inclined Tube Manometer, Industrial Filters Indicators, Industrial Flow Meter, Industrial Flow Meters, Industrial Sight Glass, Industrial Sight Glasses, Industrial U Tube Manometer, Inlined Tube Meno Meters, Installation Orifice Plate, Kerosene Fuel Meter, Level Gauge, Level Gauge And Water Level Indicators, Level Gauge For Liquid Use, Level Gauge For Pharmaceuticals, Level Gauge Indicators, Level Glass Indicator, Level Indicator, Level Indicator Float Type, Level Indicator For Tank, Level Indicators, Level Indicators For Tank, Level Instruments, Level Measurement, Level Measuring Instruments, Level Sight Glass, Level Switch, Level Switchs, Level Transmitter, Levels Indicator, Levels Indicators, Levels Indicatorss, Levels Switch, Levels Switchs, Liquid Float Level Switch, Liquid Flow Measurement, Liquid Flow Meter, Liquid Flow Rotameter, Liquid Flow Rotameters, Liquid Flow Sensor, Liquid Flow Sensor Rotameters, Liquid Flow Sensors Rotameter, Liquid Flows Rotameter, Liquid Level Float Switch, Liquid Level Gauge, Liquid Level Gauges, Liquid Level Indicator, Liquid Level Indicators, Liquid Level Indicators For Tanks, Liquid Level Measurement, Liquid Level Switch, Liquid Level Switches, Liquid Level Transmitters, Liquid Magnetic Float Level Switch, Liquid Rotameter, Low Flow Rotameters, Low Flows Rotameter, Low Flows Rotameters, Mag Level Indicators, Magnetic Float Level Switch, Magnetic Float Levels Switch, Magnetic Float Liquid Level Switch, Magnetic Flow Meter, Magnetic Flows Meters, Magnetic Inductive Flow Meters, Magnetic Level Gauge And Indicator, Magnetic Level Gauges, Magnetic Level Indicators, Magnetic Level Switches, Magnetic Level Transmitter, Magnetic Levels Indicator, Magnetic Levels Indicators, Magnetic Metal Rotameters, Magnetic Rotameter, Magnetic Rotameters, Magnetic Sanitary Flow Meter, Magnetic Tank Level Indicator, Magnetic Water Flow Meter, Magnetic Water Level Indicator, Magnetics Flows Meter, Magnetics Flows Meters, Magnetics Level Indicator, Magnetrol Level Transmitter, Mano Meters, Manometer, Measuring Rotameter, Mechanical Fuel Flow Meter, Mechanical Rotameter, Mercury Barometer, Mercury U Tube Manometer, Metal Tube Rota Meters, Metal Tube Rotameter, Metal Tube Rotameter With Switching Alarm, Metal Tube Rotmeters, Metal Tubes Rotameter, Metal Tubes Rotameters, Metals Tube Rotameter, Milk Flow Meter, Mini Level Switch, Mini Levels Switch, Mini Levels Switches, Moisture Glass Indicators, Moisture Industrial Filters, Moisture Trap Assembly, Ms Sight Glass, Multi Point Magnetic Float Level Switch, Multiple Orifice Plate, Nitrogen Rotameters, Oil Level Sight Glass, Oil Tank Level Indicator, Oil Tank Level Indicators, Online Effluent Flow Meter, Orifice Assembly, Orifice Assly, Orifice Flange, Orifice Flange Assemblies, Orifice Flange Assembly, Orifice Flange Union, Orifice Flanges Assembly, Orifice Flow Meter, Orifice Plate, Orifice Plate Design Calculation, Orifice Plate Flange, Orifice Plate Flange Assembly, Orifice Plate Flow Meter, Orifice Plate Flow Meters, Orifice Plate Meter, Orifice Plate Sizing, Orifice Plates, Orifice Plates And Flange Assembles, Orifice Plates And Flange Assemblies, Orifice Plates And Flange Assembly, Orifice Plates And Flanges Assemblies, Orifice Plates Sizing, Orifice Plates Water Flow Meter, Orifice Type Flow Meter, Orifices Assembly, Orifices Plates, Oval Gear Flow Meter, Petrochemicals Transparent Level Gauge, Petrol And Mto Fuel Meter, Pressure Manometer, Pressure Measuring Instruments, Products, Pulse Output Electromagnetic Flow Meter, Purge Rotameter, Reflex And Transparent Level Gauge, Reflex And Transparent Type Level Gauge, Reflex Glass Level Gauges, Reflex Glass Liquid Level Indicator, Reflex Indicator, Reflex Indicators, Reflex Level Indicator, Reflex Level Indicators, Reflex Levels Gauges, Reflex Liquid Level Gauge, Reflex Transparent Level Gauges, Remote Type Electro Flow Meter, Restricted Orifice Plate, Roller Type Level Indicator, Roller Type Levels Indicator, Rota Meter, Rota Meters, Rotameter Flow Meter, Rotameter Flow Meters, Rotameter Flow Rate, Rotameter Flows Meter, Rotameter Glass Tube Rotameter, Rotameter Principle, Rotameter Working, Rotameters And Flow Meter, Rotameters Working, Rotameterss, Rotametersss, Rotameterssss, Rotametersssss, Rotameterssssss, Rotametersssssss, Sanitary Electromagnetic Flow Meter, Sanitary Electromagnetic Flow Meters, Sanitary Flow Meter, Sanitary Liquid Flow Meter, Sanitary Magnetic Flow Meter, Segmental Orifice Plate, Side Mounted Float Level Switch, Side Mounted Level Indicator, Side Mounted Level Switches, Side Mounted Magnetic Level Indicator, Side Mounted Magnetic Level Switch, Side Mounted Magnetic Levels Indicator, Side Mounted Magnetic Levels Indicators, Side Mounted Magnetics Level Indicators, Side Mounted Magnetics Levels Indicator, Side Mounted Magnetics Levels Indicators, Side Mounted Tubular Level Indicator, Sight Glass Level Gauge, Sight Glasses, Single Limb Absolute Pressure Mercury Filled Manometer, Single Limb Mano Meters, Single Limb Wall Type Manometer, Single Window Sight Glass, Smart Magnetic Level Transmitter And Indicators, Steam Rotameters, Tank Float Level Indicators, Tank Level Indicator, Tank Level Indicator Float, Tank Level Indicator Float Type, Tank Level Switch, Tank Liquid Level Indicator, Tank Mounted View Glass, Tanks Level Indicator, Thread Conn Acrylic Body Rotameter, Top Mounted Levels Switches, Top Mounted Liquid Level Switch, Top Mounted Magnetic Float Liquid Level Switch, Top Mounted Magnetic Level Switch, Transmitters, Transmitterss, Transparent And Reflex Level Gauge, Transparent Level Gauge, Transparent Level Gauges, Tubular Glass Level Gauge, Tubular Level Gauge, Tubular Level Gauges, Tubular Level Indicators, Tubular Levels Indicator, U Tube Absolute Pressure Mercury Filled Manometer, U Tube Manometer, U Tube Manometers, U Tube Meno Meters, U Tube Type Manometers, U Tube Water Manometer, U Tubes Manometer, U Tubes Manometers, U Tubes Manometerss, Variable Area Flow Meter, Water Digital Flow Meter, Water Flow Meter, Water Flow Meter With Data Logger, Water Flow Meters, Water Flow Rate Meter, Water Flow Sensor Rotameter, Water Flows Meters, Water Level Gauge, Water Level Indicator, Water Level Indicators, Water Level Sensor Switch, Water Level Switch, Water Levels Indicators, Water Magnetic Flow Meter, Water Pipe Flow Meter, Water Reflex Level Indicators, Water Rotameter, Water Tank Level Gauge, Water Tank Level Indicator, Water Tank Level Indicators, Water Tank Level Switches, Water Tank Levels Indicator, Water Tank Levels Indicators, Water Tank Side Mounted Level Indicator, Water Tank Water Level Indicator, Water Tank Water Level Indicators, Waters Levels Indicators, Window Sight Glasses, Wnrf Orifice Type Flow Meters